PERI_CLK_SEL用來設定需要使用的Clock Source


P.S. 如果要使用Timer,BBPPLL必須要Enable

T0INT用來判斷Timer0是否已經發生中斷


T0PRES用來設定預除數值,T0EN用來啟動Timer0下數功能,T0AL用來設定是否自動從T0LMT_REG載入數值


自動載入的數值


Timer0下數數值設定


main.s

    .extern _start
    .set noreorder
 
    .equiv CLKCFG0,     0xb000002c
    .equiv TGLB_REG,    0xb0000100
    .equiv T0CTL_REG,   0xb0000110
    .equiv T0LMT_REG,   0xb0000114
    .equiv GPIO_CTRL_1, 0xb0000604
    .equiv GPIO_DATA_1, 0xb0000624
    .equiv LED,         (44 - 32)

    .text
_start:
    b reset
  
    .org 0x400
reset:
    li $8, GPIO_CTRL_1
    li $9, (1 << LED)
    sw $9, 0($8)

    li $8, CLKCFG0
    lw $9, 0($8)
    or $9, (1 << 4) | (1 << 3) | (1 << 2)
    sw $9, 0($8)
    
    li $8, T0LMT_REG
    li $9, 1000
    sw $9, 0($8)

    li $8, T0CTL_REG
    li $9, (1000 << 16) | (1 << 7) | (1 << 4)
    sw $9, 0($8)
loop:
    li $8, TGLB_REG
    lw $9, 0($8)
    and $9, 1
    beqz $9, loop
    nop

    li $8, GPIO_DATA_1
    xor $10, (1 << LED)
    sw $10, 0($8)
  
    li $8, TGLB_REG
    li $9, 1
    sw $9, 0($8)

    b loop
    nop

P.S. T0PRES = 1000,代表每筆下數的時間為1ms,T0LMT_REG = 1000,代表每秒產生一次中斷,需要注意的是,不管Timer0使用XTAL或者BBPPLL當作Clock Source,BBPPLL都必須要Enable